Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Med Phys ; 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38669482

ABSTRACT

BACKGROUND: Monte Carlo simulation code is commonly used for the dose calculation of boron neutron capture therapy. In the past, dose calculation was performed assuming a homogeneous mass density and elemental composition inside the tissue, regardless of the patient's age or sex. Studies have shown that the mass density varies with patient to patient, particularly for those that have undergone surgery or radiotherapy. A method to convert computed tomography numbers into mass density and elemental weights of tissues has been developed and applied in the dose calculation process using Monte Carlo codes. A recent study has shown the variation in the computed tomography number between different scanners for low- and high-density materials. PURPOSE: The aim of this study is to investigate the effect of the elemental composition inside each calculation voxel on the dose calculation and the application of the stoichiometric CT number calibration method for boron neutron capture therapy planning. METHODS: Monte Carlo simulation package Particle and Heavy Ion Transport code System was used for the dose calculation. Firstly, a homogeneous cubic phantom with the material set to ICRU soft tissue (four component), muscle, fat, and brain was modelled and the NeuCure BNCT system accelerator-based neutron source was used. The central axis depth dose distribution was simulated and compared between the four materials. Secondly, a treatment plan of the brain and the head and neck region was simulated using a dummy patient dataset. Three models were generated; (1) a model where only the fundamental materials were considered (simple model), a model where each voxel was assigned a mass density and elemental weight using (2) the Nakao20 model, and (3) the Schneider00 model. The irradiation conditions were kept the same between the different models (irradiation time and irradiation field size) and the near maximum (D1%) and mean dose to the organs at risk were calculated and compared. RESULTS: A maximum percentage difference of approximately 5% was observed between the different materials for the homogeneous phantom. With the dummy patient plan, a large dose difference in the bone (greater than 12%) and region near the low-density material (mucosal membrane, 7%-11%) was found between the different models. CONCLUSIONS: A stoichiometric CT number calibration method using the newly developed Nakao20 model was applied to BNCT dose calculation. The results indicate the importance of calibrating the CT number to elemental composition for each individual CT scanner for the purpose of BNCT dose calculation along with the consideration of heterogeneity of the material composition inside the defined region of interest.

2.
Sci Rep ; 14(1): 8265, 2024 04 09.
Article in English | MEDLINE | ID: mdl-38594281

ABSTRACT

Boron neutron capture therapy (BNCT) is a type of targeted particle radiation therapy with potential applications at the cellular level. Spinal cord gliomas (SCGs) present a substantial challenge owing to their poor prognosis and the lack of effective postoperative treatments. This study evaluated the efficacy of BNCT in a rat SCGs model employing the Basso, Beattie, and Bresnahan (BBB) scale to assess postoperative locomotor activity. We confirmed the presence of adequate in vitro boron concentrations in F98 rat glioma and 9L rat gliosarcoma cells exposed to boronophenylalanine (BPA) and in vivo tumor boron concentration 2.5 h after intravenous BPA administration. In vivo neutron irradiation significantly enhanced survival in the BNCT group when compared with that in the untreated group, with a minimal BBB scale reduction in all sham-operated groups. These findings highlight the potential of BNCT as a promising treatment option for SCGs.


Subject(s)
Boron Neutron Capture Therapy , Brain Neoplasms , Glioma , Spinal Cord Neoplasms , Rats , Animals , Brain Neoplasms/pathology , Rats, Inbred F344 , Boron , Translational Research, Biomedical , Boron Compounds/pharmacology , Glioma/pathology
3.
Med Phys ; 51(5): 3711-3724, 2024 May.
Article in English | MEDLINE | ID: mdl-38205862

ABSTRACT

BACKGROUND: In Japan, the clinical treatment of boron neutron capture therapy (BNCT) has been applied to unresectable, locally advanced, and recurrent head and neck carcinomas using an accelerator-based neutron source since June of 2020. Considering the increase in the number of patients receiving BNCT, efficiency of the treatment planning procedure is becoming increasingly important. Therefore, novel and rapid dose calculation algorithms must be developed. We developed a novel algorithm for calculating neutron flux, which comprises of a combination of a Monte Carlo (MC) method and a method based on the removal-diffusion (RD) theory (RD calculation method) for the purpose of dose calculation of BNCT. PURPOSE: We present the details of our novel algorithm and the verification results of the calculation accuracy based on the MC calculation result. METHODS: In this study, the "MC-RD" calculation method was developed, wherein the RD calculation method was used to calculate the thermalization process of neutrons and the MC method was used to calculate the moderation process. The RD parameters were determined by MC calculations in advance. The MC-RD calculation accuracy was verified by comparing the results of the MC-RD and MC calculations with respect to the neutron flux distributions in each of the cubic and head phantoms filled with water. RESULTS: Comparing the MC-RD calculation results with those of MC calculations, it was found that the MC-RD calculation accurately reproduced the thermal neutron flux distribution inside the phantom, with the exception of the region near the surface of the phantom. CONCLUSIONS: The MC-RD calculation method is useful for the evaluation of the neutron flux distribution for the purpose of BNCT dose calculation, except for the region near the surface.


Subject(s)
Algorithms , Boron Neutron Capture Therapy , Monte Carlo Method , Neutrons , Radiotherapy Planning, Computer-Assisted , Boron Neutron Capture Therapy/methods , Neutrons/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Diffusion , Radiotherapy Dosage , Phantoms, Imaging , Humans
4.
Med Phys ; 51(1): 509-521, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37672219

ABSTRACT

BACKGROUND: Evaluation of the boron dose is essential for boron neutron capture therapy (BNCT). Nevertheless, a direct evaluation method for the boron-dose distribution has not yet been established in the clinical BNCT field. To date, even in quality assurance (QA) measurements, the boron dose has been indirectly evaluated from the thermal neutron flux measured using the activation method with gold foil or wire and an assumed boron concentration in the QA procedure. Recently, we successfully conducted optical imaging of the boron-dose distribution using a cooled charge-coupled device (CCD) camera and a boron-added liquid scintillator at the E-3 port facility of the Kyoto University Research Reactor (KUR), which supplies an almost pure thermal neutron beam with very low gamma-ray contamination. However, in a clinical accelerator-based BNCT facility, there is a concern that the boron-dose distribution may not be accurately extracted because the unwanted luminescence intensity, which is irrelevant to the boron dose is expected to increase owing to the contamination of fast neutrons and gamma rays. PURPOSE: The purpose of this research was to study the validity of a newly proposed method using a boron-added liquid scintillator and a cooled CCD camera to directly observe the boron-dose distribution in a clinical accelerator-based BNCT field. METHOD: A liquid scintillator phantom with 10 B was prepared by filling a small quartz glass container with a commercial liquid scintillator and boron-containing material (trimethyl borate); its natural boron concentration was 1 wt%. Luminescence images of the boron-neutron capture reaction were obtained in a water tank at several different depths using a CCD camera. The contribution of background luminescence, mainly due to gamma rays, was removed by subtracting the luminescence images obtained using another sole liquid scintillator phantom (natural boron concentration of 0 wt%) at each corresponding depth, and a depth profile of the boron dose with several discrete points was obtained. The obtained depth profile was compared with that of calculated boron dose, and those of thermal neutron flux which were experimentally measured or calculated using a Monte Carlo code. RESULTS: The depth profile evaluated from the subtracted images indicated reasonable agreement with the calculated boron-dose profile and thermal neutron flux profiles, except for the shallow region. This discrepancy is thought to be due to the contribution of light reflected from the tank wall. The simulation results also demonstrated that the thermal neutron flux would be severely perturbed by the 10 B-containing phantom if a relatively larger container was used to evaluate a wide range of boron-dose distributions in a single shot. This indicates a trade-off between the luminescence intensity of the 10 B-added phantom and its perturbation effect on the thermal neutron flux. CONCLUSIONS: Although a partial discrepancy was observed, the validity of the newly proposed boron-dose evaluation method using liquid-scintillator phantoms with and without 10 B was experimentally confirmed in the neutron field of an accelerator-based clinical BNCT facility. However, this study has some limitations, including the trade-off problem stated above. Therefore, further studies are required to address these limitations.


Subject(s)
Boron Neutron Capture Therapy , Boron , Humans , Boron Neutron Capture Therapy/methods , Feasibility Studies , Neutrons , Phantoms, Imaging , Monte Carlo Method , Optical Imaging , Radiotherapy Dosage
5.
Med Phys ; 51(2): 1351-1363, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38153111

ABSTRACT

BACKGROUND: The out-of-field radiation dose for boron neutron capture therapy (BNCT), which results from both neutrons and γ-rays, has not been extensively evaluated. To safely perform BNCT, the neutron and γ-ray distributions inside the treatment room and the whole-body dose should be evaluated during commissioning. Although, certain previous studies have evaluated the whole-body dose in the clinical research phase, no institution providing BNCT covered by health insurance has yet validated the neutron distribution inside the room and the whole-body dose. PURPOSE: To validate the Monte Carlo model of the BNCT irradiation room extended for the whole-body region and evaluate organ-at-risk (OAR) doses using the validated model with a human-body phantom. METHODS: First, thermal neutron distribution inside the entire treatment room was measured by placing Au samples on the walls of the treatment room. Second, neutron and gamma-ray dose-rate distributions inside a human-body water phantom were measured. Both lying and sitting positions were considered. Bare Au, Au covered by Cd (Au+Cd), In, Al, and thermoluminescent dosimeters were arranged at 11 points corresponding to locations of the OARs inside the phantom. After the irradiation, γ-ray peaks emitted from the samples were measured by a high-purity germanium detector. The measured counts were converted to the reaction rate per unit charge of the sample. These measurements were compared with results of simulations performed with the Particle and Heavy Ion Transport code System (PHITS). A male adult mesh-type reference computational phantom was used to evaluate OAR doses in the whole-body region. The relative biological effectiveness (RBE)-weighted doses and dose-volume histograms (DVHs) for each OAR were evaluated. The median dose (D50% ) and near-maximum dose (D2% ) were evaluated for 14 OARs in a 1-h-irradiation process. The evaluated RBE-weighted doses were converted to equivalent doses in 2 Gy fractions. RESULTS: Experimental results within 60 cm from the irradiation center agreed with simulation results within the error bars except at ±20, 30 cm, and those over 70 cm corresponded within one digit. The experimental results of reaction rates or γ-ray dose rate for lying and sitting positions agreed well with the simulation results within the error bars at 8, 4, 11, 7 and 7, 4, 7, 6, 5, 6 out of 11 points, respectively, for Au, Au+Cd, In, Al, and TLD. Among the detectors, the discrepancies in reaction rates between experiment and simulation were most common for Au+Cd, but were observed randomly for measurement points (brain, lung, etc.). The experimental results of γ-ray dose rates were systematically lower than simulation results at abdomen and waist regions for both positions. Extending the PHITS model to the whole-body region resulted in higher doses for all OARs, especially 0.13 Gy-eq increase for D50% of the left salivary gland. CONCLUSION: The PHITS model for clinical BNCT for the whole-body region was validated, and the OAR doses were then evaluated. Clinicians and medical physicists should know that the out-of-field radiation increases the OAR dose in the whole-body region.


Subject(s)
Boron Neutron Capture Therapy , Humans , Boron Neutron Capture Therapy/methods , Cadmium , Computer Simulation , Monte Carlo Method , Neutrons , Radiometry/methods , Radiotherapy Dosage
6.
Biology (Basel) ; 12(9)2023 Sep 15.
Article in English | MEDLINE | ID: mdl-37759639

ABSTRACT

High-grade gliomas present a significant challenge in neuro-oncology because of their aggressive nature and resistance to current therapies. Boron neutron capture therapy (BNCT) is a potential treatment method; however, the boron used by the carrier compounds-such as 4-borono-L-phenylalanine (L-BPA)-have limitations. This study evaluated the use of boron-conjugated 4-iodophenylbutanamide (BC-IP), a novel boron compound in BNCT, for the treatment of glioma. Using in vitro drug exposure experiments and in vivo studies, we compared BC-IP and BPA, with a focus on boron uptake and retention characteristics. The results showed that although BC-IP had a lower boron uptake than BPA, it exhibited superior retention. Furthermore, despite lower boron accumulation in tumors, BNCT mediated by BC-IP showed significant survival improvement in glioma-bearing rats compared to controls (not treated animals and neutrons only). These results suggest that BC-IP, with its unique properties, may be an alternative boron carrier for BNCT. Further research is required to optimize this potential treatment modality, which could significantly contribute to advancing the treatment of high-grade gliomas.

7.
J Radiat Res ; 64(6): 859-869, 2023 Nov 21.
Article in English | MEDLINE | ID: mdl-37717596

ABSTRACT

Recently, boron neutron capture therapy (BNCT) has been attracting attention as a minimally invasive cancer treatment. In 2020, the accelerator-based BNCT with L-BPA (Borofalan) as its D-sorbitol complex (Steboronine®) for head and neck cancers was approved by Pharmaceutical and Medical Devices Agency for the first time in the world. As accelerator-based neutron generation techniques are being developed in various countries, the development of novel tumor-selective boron agents is becoming increasingly important and desired. The Japanese Society of Neutron Capture Therapy believes it is necessary to propose standard evaluation protocols at each stage in the development of boron agents for BNCT. This review summarizes recommended experimental protocols for in vitro and in vivo evaluation methods of boron agents for BNCT based on our experience with L-BPA approval.


Subject(s)
Boron Neutron Capture Therapy , Head and Neck Neoplasms , Humans , Boron , Boron Compounds/therapeutic use , Boron Neutron Capture Therapy/methods , Neutrons , Review Literature as Topic
8.
Cancers (Basel) ; 15(16)2023 Aug 14.
Article in English | MEDLINE | ID: mdl-37627119

ABSTRACT

Boron neutron capture therapy (BNCT) is a tumor-selective particle radiotherapy. It combines preferential boron accumulation in tumors and neutron irradiation. The recent initiation of BNCT clinical trials employing hospital-based accelerators rather than nuclear reactors as the neutron source will conceivably pave the way for new and more numerous clinical trials, leading up to much-needed randomized trials. In this context, it would be interesting to consider the implementation of new boron compounds and strategies that will significantly optimize BNCT. With this aim in mind, we analyzed, in this review, those articles published between 2020 and 2023 reporting new boron compounds and strategies that were proved therapeutically useful in in vitro and/or in vivo radiobiological studies, a critical step for translation to a clinical setting. We also explored new pathologies that could potentially be treated with BNCT and newly developed theranostic boron agents. All these radiobiological advances intend to solve those limitations and questions that arise during patient treatment in the clinical field, with BNCT and other therapies. In this sense, active communication between clinicians, radiobiologists, and all disciplines will improve BNCT for cancer patients, in a cost- and time-effective way.

9.
J Radiat Res ; 64(5): 811-815, 2023 Sep 22.
Article in English | MEDLINE | ID: mdl-37607589

ABSTRACT

A neutron beam for boron neutron capture therapy (BNCT) of deep-seated tumours is designed to maintain a high flux of epithermal neutrons, while keeping the thermal and fast neutron component as low as possible. These neutrons (thermal and fast) have a high relative biological effectiveness in comparison with high energy photon beams used for conventional X-ray radiotherapy. In the past, neutrons for the purpose of BNCT were generated using nuclear reactors. However, there are various challenges that arise when installing a reactor in a hospital environment. From 2006, the Kyoto University Research Reactor Institute, in collaboration with Sumitomo Heavy Industries, began the development of an accelerator-based neutron source for clinical BNCT in a bid to overcome the shortcomings of a nuclear reactor-based neutron source. Following installation and beam performance testing, in vitro studies were performed to assess the biological effect of the neutron beam. Four different cell lines were prepared and irradiated using the accelerator-based neutron source. Following neutron and gamma ray irradiation, the survival curve for each cell line was calculated. The biological end point to determine the relative biological effectiveness (RBE) was set to 10% cell survival, and the D10 for each cell line was determined. The RBE of the accelerator-based neutron beam was evaluated to be 2.62.


Subject(s)
Boron Neutron Capture Therapy , Neoplasms , Humans , Relative Biological Effectiveness , Cyclotrons , Neutrons
10.
J Radiat Res ; 64(3): 602-611, 2023 May 25.
Article in English | MEDLINE | ID: mdl-37100599

ABSTRACT

To treat superficial tumors using accelerator-based boron neutron capture therapy (ABBNCT), a technique was investigated, based on which, a single-neutron modulator was placed inside a collimator and was irradiated with thermal neutrons. In large tumors, the dose was reduced at their edges. The objective was to generate a uniform and therapeutic intensity dose distribution. In this study, we developed a method for optimizing the shape of the intensity modulator and irradiation time ratio to generate a uniform dose distribution to treat superficial tumors of various shapes. A computational tool was developed, which performed Monte Carlo simulations using 424 different source combinations. We determined the shape of the intensity modulator with the highest minimum tumor dose. The homogeneity index (HI), which evaluates uniformity, was also derived. To evaluate the efficacy of this method, the dose distribution of a tumor with a diameter of 100 mm and thickness of 10 mm was evaluated. Furthermore, irradiation experiments were conducted using an ABBNCT system. The thermal neutron flux distribution outcomes that have considerable impacts on the tumor's dose confirmed a good agreement between experiments and calculations. Moreover, the minimum tumor dose and HI improved by 20 and 36%, respectively, compared with the irradiation case wherein a single-neutron modulator was used. The proposed method improves the minimum tumor volume and uniformity. The results demonstrate the method's efficacy in ABBNCT for the treatment of superficial tumors.


Subject(s)
Boron Neutron Capture Therapy , Neoplasms , Humans , Boron Neutron Capture Therapy/methods , Neoplasms/radiotherapy , Neutrons , Radiotherapy Dosage , Monte Carlo Method
11.
Biomed Phys Eng Express ; 9(3)2023 04 06.
Article in English | MEDLINE | ID: mdl-37021631

ABSTRACT

We developed a 'hybrid algorithm' that combines the Monte Carlo (MC) and point-kernel methods for fast dose calculation in boron neutron capture therapy. The objectives of this study were to experimentally verify the hybrid algorithm and to verify the calculation accuracy and time of a 'complementary approach' adopting both the hybrid algorithm and the full-energy MC method. In the latter verification, the results were compared with those obtained using the full-energy MC method alone. In the hybrid algorithm, the moderation process of neutrons is simulated using only the MC method, and the thermalization process is modeled as a kernel. The thermal neutron fluxes calculated using only this algorithm were compared with those measured in a cubic phantom. In addition, a complementary approach was used for dose calculation in a geometry simulating the head region, and its computation time and accuracy were verified. The experimental verification indicated that the thermal neutron fluxes calculated using only the hybrid algorithm reproduced the measured values at depths exceeding a few centimeters, whereas they overestimated those at shallower depths. Compared with the calculation using only the full-energy MC method, the complementary approach reduced the computation time by approximately half, maintaining nearly same accuracy. When focusing on the calculation only using the hybrid algorithm only for the boron dose attributed to the reaction of thermal neutrons, the computation time was expected to reduce by 95% compared with the calculation using only the full-energy MC method. In conclusion, modeling the thermalization process as a kernel was effective for reducing the computation time.


Subject(s)
Boron Neutron Capture Therapy , Radiotherapy Dosage , Boron Neutron Capture Therapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Neutrons , Algorithms
12.
Biology (Basel) ; 12(3)2023 Feb 27.
Article in English | MEDLINE | ID: mdl-36979069

ABSTRACT

Integrin αvß3 is more highly expressed in high-grade glioma cells than in normal tissues. In this study, a novel boron-10 carrier containing maleimide-functionalized closo-dodecaborate (MID), serum albumin as a drug delivery system, and cyclic arginine-glycine-aspartate (cRGD) that can target integrin αvß3 was developed. The efficacy of boron neutron capture therapy (BNCT) targeting integrin αvß3 in glioma cells in the brain of rats using a cRGD-functionalized MID-albumin conjugate (cRGD-MID-AC) was evaluated. F98 glioma cells exposed to boronophenylalanine (BPA), cRGD-MID-AC, and cRGD + MID were used for cellular uptake and neutron-irradiation experiments. An F98 glioma-bearing rat brain tumor model was used for biodistribution and neutron-irradiation experiments after BPA or cRGD-MID-AC administration. BNCT using cRGD-MID-AC had a sufficient cell-killing effect in vitro, similar to that with BNCT using BPA. In biodistribution experiments, cRGD-MID-AC accumulated in the brain tumor, with the highest boron concentration observed 8 h after administration. Significant differences were observed between the untreated group and BNCT using cRGD-MID-AC groups in the in vivo neutron-irradiation experiments through the log-rank test. Long-term survivors were observed only in BNCT using cRGD-MID-AC groups 8 h after intravenous administration. These findings suggest that BNCT with cRGD-MID-AC is highly selective against gliomas through a mechanism that is different from that of BNCT with BPA.

13.
Cancers (Basel) ; 15(4)2023 Feb 06.
Article in English | MEDLINE | ID: mdl-36831378

ABSTRACT

BACKGROUND: Boron neutron capture therapy (BNCT) has been adapted to high-grade gliomas (HG); however, some gliomas are refractory to BNCT using boronophenylalanine (BPA). In this study, the feasibility of BNCT targeting the 18 kDa translocator protein (TSPO) expressed in glioblastoma and surrounding environmental cells was investigated. METHODS: Three rat glioma cell lines, an F98 rat glioma bearing brain tumor model, DPA-BSTPG which is a boron-10 compound targeting TSPO, BPA, and sodium borocaptate (BSH) were used. TSPO expression was evaluated in the F98 rat glioma model. Boron uptake was assessed in three rat glioma cell lines and in the F98 rat glioma model. In vitro and in vivo neutron irradiation experiments were performed. RESULTS: DPA-BSTPG was efficiently taken up in vitro. The brain tumor has 16-fold higher TSPO expressions than its brain tissue. The compound biological effectiveness value of DPA-BSTPG was 8.43 to F98 rat glioma cells. The boron concentration in the tumor using DPA-BSTPG convection-enhanced delivery (CED) administration was approximately twice as high as using BPA intravenous administration. BNCT using DPA-BSTPG has significant efficacy over the untreated group. BNCT using a combination of BPA and DPA-BSTPG gained significantly longer survival times than using BPA alone. CONCLUSION: DPA-BSTPG in combination with BPA may provide the multi-targeted neutron capture therapy against HG.

14.
Eur J Hybrid Imaging ; 6(1): 35, 2022 Dec 05.
Article in English | MEDLINE | ID: mdl-36464732

ABSTRACT

BACKGROUND: The goal of the study was to evaluate the diagnostic ability of 18F-FBPA PET/CT for malignant tumors. Findings from 18F-FBPA and 18F-FDG PET/CT were compared with pathological diagnoses in patients with malignant tumors or benign lesions. METHODS: A total of 82 patients (45 males, 37 females; median age, 63 years; age range, 20-89 years) with various types of malignant tumors or benign lesions, such as inflammation and granulomas, were examined by 18F-FDG and 18F-FBPA PET/CT. Tumor uptake of FDG or FBPA was quantified using the maximum standardized uptake value (SUVmax). The final diagnosis was confirmed by cytopathology or histopathological findings of the specimen after biopsy or surgery. A ROC curve was constructed from the SUVmax values of each PET image, and the area under the curve (AUC) and cutoff values were calculated. RESULTS: The SUVmax for 18F-FDG PET/CT did not differ significantly for malignant tumors and benign lesions (10.9 ± 6.3 vs. 9.1 ± 2.7 P = 0.62), whereas SUVmax for 18F-FBPA PET/CT was significantly higher for malignant tumors (5.1 ± 3.0 vs. 2.9 ± 0.6, P < 0.001). The best SUVmax cutoffs for distinguishing malignant tumors from benign lesions were 11.16 for 18F-FDG PET/CT (sensitivity 0.909, specificity 0.390) and 3.24 for 18F-FBPA PET/CT (sensitivity 0.818, specificity 0.753). ROC analysis showed significantly different AUC values for 18F-FDG and 18F-FBPA PET/CT (0.547 vs. 0.834, p < 0.001). CONCLUSION: 18F-FBPA PET/CT showed superior diagnostic ability over 18F-FDG PET/CT in differential diagnosis of malignant tumors and benign lesions. The results of this study suggest that 18F-FBPA PET/CT diagnosis may reduce false-positive 18F-FDG PET/CT diagnoses.

15.
J Radiat Res ; 63(6): 866-873, 2022 Dec 06.
Article in English | MEDLINE | ID: mdl-36149023

ABSTRACT

The distribution of the thermal neutron flux has a significant impact on the treatment efficacy. We developed an irradiation method of overlapping irradiation fields using intensity modulators for the treatment of superficial tumors with the aim of expanding the indications for accelerator-based boron neutron capture therapy (BNCT). The shape of the intensity modulator was determined and Monte Carlo simulations were carried out to determine the uniformity of the resulting thermal neutron flux distribution. The intensity modulators were then fabricated and irradiation tests were conducted, which resulted in the formation of a uniform thermal neutron flux distribution. Finally, an evaluation of the tumor dose distribution showed that when two irradiation fields overlapped, the minimum tumor dose was 27.4 Gy-eq, which was higher than the tumor control dose of 20 Gy-eq. Furthermore, it was found that the uniformity of the treatment was improved 47% as compared to the treatment that uses a single irradiation field. This clearly demonstrates the effectiveness of this technique and the possibility of expanding the indications to superficially located tumors.


Subject(s)
Boron Neutron Capture Therapy , Neoplasms , Humans , Neoplasms/radiotherapy
16.
Appl Radiat Isot ; 189: 110420, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36108532

ABSTRACT

Salvage surgery after radiation therapy is known to be associated with a high incidence of postoperative complications. We describe a case of a successful salvage surgery after BNCT. In our patient with head and neck carcinoma, cervical lymph node recurrence with adhesion to a large vessel occurred after conventional radiotherapy. This lesion responded well to BNCT. Salvage surgery was subsequently performed to remove the residual tumor. Histopathologically, the isolated tissue contained tumor cells in its center and the surrounding tissue showed severe fibrosis. However, the tissue outside of the irradiation area had almost no fibrosis. BNCT may facilitate salvage surgery after radiotherapy because it causes less injury to the surrounding tissue than conventional radiotherapy. Our experience suggests that BNCT may be a feasible preoperative treatment in patients with inoperable lesions or in those who strongly desire preservation of function.


Subject(s)
Boron Neutron Capture Therapy , Head and Neck Neoplasms , Boron Compounds , Boron Neutron Capture Therapy/methods , Head and Neck Neoplasms/radiotherapy , Humans , Neoplasm Recurrence, Local/radiotherapy , Neoplasm, Residual/radiotherapy , Salvage Therapy
17.
Sci Rep ; 12(1): 13778, 2022 08 12.
Article in English | MEDLINE | ID: mdl-35962034

ABSTRACT

In June 2020, the Japanese government approved boron neutron capture therapy for the treatment of head and neck cancer. The treatment is usually performed in a single fraction, with the neutron irradiation time being approximately 30-60 min. As neutrons scatter in air and loses its intensity, it is preferable to bring the patient as close to the beam port as possible to shorten the irradiation time. However, this can be a challenge, especially for patients with head and neck cancer, as the shoulders are an obstacle to a clean positioning. In this study, a novel neutron collimation system for an accelerator based neutron source was designed to allow for a more comfortable treatment, without compromising the irradiation time. Experimental measurements confirmed the simulation results and showed the new collimator can reduce the irradiation time by approximately 60% (under the same condition where the distance between the source and the patient surface was kept the same). The dose delivered to the surrounding healthy tissue was reduced with the new collimator, showing a 25% decrease in the D50 of the mucosal membrane. Overall, the use of the newly designed collimator will allow for a more comfortable treatment of the head and neck region, reduce the treatment time, and reduce the dose delivered to the surrounding healthy tissue.


Subject(s)
Boron Neutron Capture Therapy , Head and Neck Neoplasms , Boron Neutron Capture Therapy/methods , Head and Neck Neoplasms/radiotherapy , Humans , Monte Carlo Method , Neutrons , Radiotherapy Dosage
18.
Med Phys ; 49(10): 6609-6621, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35941788

ABSTRACT

PURPOSE: The aim of this study is to design and evaluate a neutron filtration system to improve the dose distribution of an accelerator-based neutron capture therapy system. METHODS: An LiF-sintered plate composed of 99%-enriched 6 Li was utilized to filter out low-energy neutrons to increase the average neutron energy at the beam exit. A 5-mm thick filter to fit inside a 12-cm diameter circular collimator was manufactured, and experimental measurements were performed to measure the thermal neutron flux and gamma-ray dose rate inside a water phantom. The experimental measurements were compared with the Monte Carlo simulation, particle, and heavy ion transport code system. Following the experimental verification, three filter designs were modeled, and the thermal neutron flux and the biologically weighted dose distribution inside a phantom were simulated. Following the phantom simulation, a dummy patient CT dataset was used to simulate a boron neutron capture therapy (BNCT) irradiation of the brain. A mock tumor located at 4, 6, 8 cm along the central axis and 4-cm off-axis was set, and the dose distribution was simulated for a maximum total biologically weighted brain dose of 12.5 Gy with a beam entering from the vertex. RESULTS: All three filters improved the beam penetration of the accelerator-based neutron source. Filter design C was found to be the most suitable filter, increasing the advantage depth from 9.1 to 9.9 cm. Compared with the unfiltered beam, the mean weighted dose in the tumor located at a depth of 8 cm along the beam axis was increased by ∼25%, and 34% for the tumor located at a depth of 8 cm and off-axis by 4 cm. CONCLUSION: A neutron filtration system for an accelerator-based BNCT system was investigated using Monte Carlo simulation. The proposed filter design significantly improved the dose distribution for the treatment of deep targets in the brain.


Subject(s)
Boron Neutron Capture Therapy , Neoplasms , Neutron Capture Therapy , Humans , Monte Carlo Method , Neutrons , Water
19.
Med Phys ; 49(8): 4944-4954, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35758307

ABSTRACT

BACKGROUND: Patients who undergo accelerator-based (AB) boron neutron capture therapy (BNCT) for head and neck cancer in the sitting position are generally uncomfortably immobilized, and patient motion during this treatment may be greater than that in other radiotherapy techniques. Furthermore, the treatment time of BNCT is relatively long (up to approximately 1 h), which increases the possibility of patient movement during treatment. As most BNCT irradiations are performed in a single fraction, the dosimetric error due to patient motion is of greater consequence and needs to be evaluated and accounted for. Several treatment parameters are required for BNCT dose calculation. PURPOSE: To investigate the dosimetric impacts (DIs) against position errors using a simple cylindrical phantom for an AB-BNCT system under different treatment parameter settings. METHODS: The treatment plans were created in RayStation and the dose calculation was performed using the NeuCure® dose engine. A cylindrical phantom (16 cm diameter × 20 cm height) made of soft tissue was modeled. Dummy tumors in the form of a 3-cm-diameter sphere were arranged at depths of 2.5 and 6.5 cm (denoted by T2.5 and T6.5 , respectively). Reference plans were created by setting the following parameters: collimator size = 10, 12, or 15 cm in diameter, collimator-to-surface distance (CSD) = 4.0 or 8.0 cm, tumor-to-blood ratio (T/B ratio) using 18 F-fluoro-borono-phenylalanine = 2.5 or 5.0, and 10 B concentration in blood = 20, 25, or 30 ppm. The prescribed dose was D95%  ≥ 20 Gy-eq for both T2.5 and T6.5 . Based on the reference plans, phantom-shifted plans were created in 26 directions [all combinations of left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions) and three distances (1.0, 2.0, and 3.0 cm). The DIs were evaluated at D80% of the tumors. The shift direction dependency of the DI in the LR, AP, and SI directions was evaluated by conducting a multiple regression analysis (MRA) and other analyses where required. RESULTS: The coefficients of the MRA of the DIs for LR, AP, and SI shifts were -0.08, 2.16, and -0.04 (p-values = 0.084, <0.01, and 0.334) for T2.5 and -0.05, 2.08, and 0.15 (p-values = 0.526, <0.01, and 0.065) for T6.5 , respectively. The analysis of variance showed that DIs due to the AP shift were significantly greater for smaller collimator sizes on T2.5 and smaller CSD on T6.5 . Dose reduction due to SI or LR (lateral) shifts was significantly greater for smaller collimator sizes on both T2.5 and T6.5 and smaller CSD on T2.5 , according to the Student's t-test. There were no significant differences in the DIs against both the AP shift and the lateral shift between the different T/B ratios and 10 B concentrations. CONCLUSION: The DIs were largely affected by the shift in the AP direction and were influenced by the different treatment parameters.


Subject(s)
Boron Neutron Capture Therapy , Boron Neutron Capture Therapy/methods , Humans , Monte Carlo Method , Phantoms, Imaging , Radiometry , Radiotherapy Dosage
20.
Med Phys ; 49(3): 1822-1830, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34958515

ABSTRACT

PURPOSE: Optical imaging of ionizing radiation is a possible method for dose distribution measurements. However, it is not clear whether the imaging method is also applicable to neutrons. To clarify this, we performed the imaging of neutrons in water from boron neutron capture therapy (BNCT) systems. Such systems require efficient distribution measurements of neutrons for quality assessment (QA) of the beams. METHOD: A water-filled phantom was irradiated from the side with an epithermal neutron beam, in which a lithium-containing zinc sulfate (Li-ZnS(Ag)) plate was set in the beam direction, and during this irradiation the scintillation of the plate was imaged using a cooled charge-coupled device (CCD) camera. In the imaging, Li-6 in the Li-ZnS(Ag) plate captures neutrons and converts them to alpha particles (He-4) and tritium (H-3), while ZnS(Ag) in the Li-ZnS(Ag) plate produces scintillation light in the plate. We also conducted Monte Carlo simulation and compared its results with the experimental results. RESULTS: The image of the emitted light from the Li-ZnS(Ag) plate was clearly obtained with an imaging time of 0.5 s. The depth and lateral profiles of the measured image using the Li-ZnS(Ag) plate showed the same shapes as the neutron distributions measured with gold foil, within a difference of 8%. The destructive effect of neutrons on the CCD camera increased approximately three times, but the unit was still working after the measurement. CONCLUSION: The optical imaging of neutrons in water is possible, and it has the potential to be a new method for efficient QA as well as for research on neutrons.


Subject(s)
Boron Neutron Capture Therapy , Boron Neutron Capture Therapy/methods , Lithium , Monte Carlo Method , Neutrons , Optical Imaging , Water , Zinc , Zinc Sulfate